Flared - Flaring and Connection Procedure
The Flare Flange connection consists of pipe suitable for cold forming (reference pages B6-B7),
flare flanges, flare cones with elastomer seals and bolting hardware.

Step 1: Cut pipe end square, deburr and clean.
Slip flange onto the pipe before flaring. Place
pipe into the flaring machine with the correct
dies and flaring cone to suit the pipe size.
|

Step 2: Pipe is to protrude to the stop on the die.
Lubricate the flaring cone, start the machine, flare
the pipe end until fully formed against the die.
Stop the machine, remove the pipe from the die.
|

Step 3: Clean and visually inspect the flare. The
surface of the flare should be smooth and free of
any defects.
|

Step 4: Select the correct pipe cone style
(ref. pgs. B4-B5). Insert pipe cone into the
flared end of the pipe (use rubber hammer if
required).
|

Step 5: Select the required bolting hardware
from section Section R of this catalogue.
|

Step 6: Tighten bolts to the torque values
specified. Always tighten bolts in a cross-over
sequence and ensure that the flanges are
parallel.
|
|